Solid Optics GLC-BX-U40-SO transceiver

On backorder – delivery in ± 2 business days

SFP - 1G BiDi BX40-U - 40 km - TX 1310 nm / RX 1490 nm - OS2

1. Distance
2. Side of the link

BiDi only works as a pair over one fibre: this U on one end, GLC-BX-D40-SO on the other, at the same distance. Which end is U doesn't matter technically, as long as the other end is D.

Coding

Pick the vendor of your switch or router, for example Juniper. We code the module for that platform before shipping, at no extra cost. MSA (Generic) is for equipment without a vendor check.

Available coded for 21 vendors

Cisco, Juniper, Brocade, Arista, Huawei, HPE, Aruba (HPE), Dell, Extreme, Nokia, Mellanox/NVIDIA, Alcatel-Lucent, Fortinet, Palo Alto Networks, Ciena, Calix, MikroTik, Ubiquiti, Netgear, D-Link and Allied Telesis. Vendor not listed? Ask us.

Configuration
Distance
40 km
Wavelength
1310nm TX/1490nm RX
SKU
GLC-BX-U40-SO
Specifications
General
Form factor
SFP
Data rate
1 Gb/s
Standard
1G BiDi BX40-U
Media
OS2 (single-mode)
Connector
LC simplex
Reach
40 km
DOM/DDM
Yes
Optical
Wavelength
TX 1310 nm, RX 1490 nm
TX power
-5 to 0 dBm
RX sensitivity
-24 dBm
RX overload
-3 dBm
Power budget
19 dB
BiDi side
U, pairs with GLC-BX-D40-SO
Environment
Operating temperature
0 to 70 °C (COM)
Download datasheet (PDF)
€22.00
excl. VAT

€26.62 incl. VAT

Pricing is based on your current configuration.

On backorder – delivery in ± 2 business days
1

Nxt-Level Service

We offer same-day delivery and installation to keep your infrastructure up and running without delay.

Same-day Amsterdam

≤ 45km from Almere

We deliver in and around Amsterdam to offices, business sites and data centres, such as Science Park, Zuidoost and Schiphol-Rijk.

Same-day NL

> 45km from Almere

Urgent delivery available to customer sites and data centres in the rest of the Netherlands.

Optics from Solid Optics

  • Lifetime warranty from Solid Optics on every transceiver
  • A test report with every unit
  • Tested on the platform the optic is meant for
  • Not sure? We test on your equipment first
  • Ships from Almere, same-day delivery in Amsterdam available
See our services →

Fiber at home (AON)?

This module can sometimes replace your provider's box, but only on AON. First check what your provider delivers at your address.

Go to the SFP checker

About the GLC-BX-U40

The GLC-BX-U40 is an SFP transceiver for 1G BiDi BX40-U: 1 Gb/s over single-mode fiber (OS2) up to 40 km, at TX 1310 nm / RX 1490 nm, with LC simplex connector and DOM/DDM monitoring. BiDi runs over a single fiber: fit the GLC-BX-D40 at the other end. Together they form a U/D pair, so always order both. Available generic (MSA) or pre-coded for 21 vendors, including Cisco, Juniper and Brocade: pick your equipment's vendor under Coding and we code it before shipping, at no extra cost. Tested, with test report and lifetime warranty.

Also known as: GLC-BX-U40 - SFP 1G BiDi BX40-U - SFP BX40-U - 1G BX40-U - 1G BiDi SFP 40 km - 1G SFP 40 km - GLC-BX-UD-PAIR-40

SFP-1G BiDi: all versions

VersionStandardReachWavelengthMediaPrice excl. VAT
GLC-BX-D201G BiDi BX20-D20 km1490/1310 nmOS2€13.00In stock
GLC-BX-U201G BiDi BX20-U20 km1310/1490 nmOS2€13.00In stock
GLC-BX-U401G BiDi BX40-U40 km1310/1490 nmOS2€22.00Backorder
GLC-BX-D401G BiDi BX40-D40 km1490/1310 nmOS2€22.00Backorder
GLC-BX-U801G BiDi BX80-U80 km1490/1550 nmOS2€80.00Backorder
GLC-BX-D801G BiDi BX80-D80 km1550/1490 nmOS2€80.00Backorder

SFP 1G BiDi: how to pick the right pair

Only one fiber free between two sites, or don't want to burn two fibers on a single 1G link? Then you want a BiDi SFP. Below: how BiDi works, why you always order a U and a D module, and which reach and coding to pick.

One fiber, two wavelengths

A regular duplex SFP uses two fibers: one to transmit, one to receive. A BiDi SFP does both over a single single-mode fiber. Each end transmits on a different wavelength, and a built-in WDM filter separates outgoing from incoming light. For 1G BiDi up to 40 km those are 1310 nm and 1490 nm; for 80 km, 1490 nm and 1550 nm.

Always order a pair: U and D

Because the wavelengths have to mirror each other, every link needs two different modules. At 20 and 40 km the U variant transmits at 1310 nm and receives at 1490 nm; the D variant does the opposite. Two U's or two D's will never give you link, however clean your fiber is. The SKU tells you straight away: GLC-BX-U20-SO and GLC-BX-D20-SO together make a 20 km pair. Pick the wavelength for one end in the selector and add its counterpart right away.

Reach: BX10, BX20, BX40, BX80

The number in the name is the reach in kilometres. 1000BASE-BX10 is the IEEE standard for 10 km; BX20, BX40 and BX80 are common market names that follow the same logic. These are the pairs you can order from us:

  • 20 km — GLC-BX-U20-SO (1310/1490 nm) and GLC-BX-D20-SO (1490/1310 nm)
  • 40 km — GLC-BX-U40-SO (1310/1490 nm) and GLC-BX-D40-SO (1490/1310 nm)
  • 80 km — GLC-BX-U80-SO (1490/1550 nm) and GLC-BX-D80-SO (1550/1490 nm)

Always pair a U and D of the same reach, and don't go bigger than you need. A 40 or 80 km optic on a short link can overload the receiver at the far end; then you need an attenuator. After plugging in, read the RX power via DOM so you know where you stand. The 80 km pair runs on 1490/1550 nm because single-mode fiber has much lower attenuation around 1550 nm than around 1310 nm. So a U80 only works with a D80.

Connector and fiber

All our BiDi modules have a simplex LC connector: one fiber, one LC. If your fiber comes in on SC, use an SC-LC patch cord. An SC simplex module, FTU conversion cable or coupler is available on request. Use single-mode fiber (OS2), not multimode. Need 10G? Pick the SFP 10G BiDi on 1270/1330 nm.

Coding for your platform

Many switches read the vendor ID from the optic's EEPROM and log a warning or keep the port down for a module they don't recognise. So pick your platform under coding: Cisco, Juniper, Arista, MikroTik, Ubiquiti or one of the other vendors in the list. We code the module before it ships. For switches without a vendor check, pick MSA (Generic). Want a spare pair ready for when a link drops? Read how to sort spares and same-day replacement.

Frequently asked questions

Can I connect a BiDi SFP to a regular duplex SFP?

No. A duplex SFP transmits and receives over two fibers, a BiDi SFP over one fiber on two wavelengths. Both ends of the link need a BiDi module: one U and one D of the same reach.

What is the difference between GLC-BX-U and GLC-BX-D?

At 20 and 40 km the U module transmits at 1310 nm and receives at 1490 nm; the D module does the opposite. At 80 km it is 1490/1550 nm. Each link needs one of each. For a point-to-point link it doesn't matter which end gets the U or the D, as long as they face each other.

What distances are available for 1G BiDi?

IEEE defines 1000BASE-BX10 for 10 km. From us you can order pairs for 20 and 40 km (1310/1490 nm) and 80 km (1490/1550 nm). Pick the smallest reach that covers your distance; an optic that is too strong for a short link needs an attenuator.

Does a BiDi SFP work on multimode fiber?

No. These 1G BiDi SFPs are made for single-mode fiber (OS2). If you have multimode in the ground, pick a duplex multimode optic such as 1000BASE-SX.