100G BiDi (QSFP28): 100G over one fiber, and how it differs from 1G and 10G
Only one fiber but you need 100G? How a 100G BiDi QSFP28 works, how it differs from 1G and 10G BiDi, BX20 or BX40, FEC, attenuators and what to order.
You have one spare single-mode fiber between two buildings or two sites, or you lease dark fiber and don't want to pay for two strands. At 10G you solved that with a BiDi pair. Now the link has to go to 100G. This article tells you whether that works, how a 100G BiDiBiDi Bidirectional transceiver: transmits and receives over a single fiber on two different wavelengths (for example 1310/1550 nm). Always deployed in pairs with mirrored wavelengths. really differs from the 1G and 10G modules you know, and which pair to order.
Yes, 100G BiDi exists: one fiber, one QSFP28 per end
A 100G BiDi is a QSFP28 with a simplex LC. It transmits and receives over one single-mode fiber, each direction on its own wavelengthWavelength The wavelength of the light, in nanometres. Common values are 850 nm (multimode), 1310 nm and 1550 nm (single-mode); both ends of a link must match.. As with 1G and 10G, every type comes as a U and a D module that mirror each other. We sell two:
| Type | U transmits / receives | D transmits / receives | Reach | Power budget / min. loss |
|---|---|---|---|---|
| BX20 | 1290 / 1310 nm | 1310 / 1290 nm | 20 km | 9.8 dB |
| BX40 | 1304.58 / 1309.14 nm | 1309.14 / 1304.58 nm | 40 km | min. 9.5 dB link loss |
Pricing is per module, so one link means ordering two, for example QSFP-100G-BX20U-SO plus QSFP-100G-BX20D-SO. Why it always has to be a mirrored pair is covered in BiDi pairs explained.
What's different from 1G and 10G
- One PAM4 signal per direction — 1G and 10G BiDi use NRZ, two signal levels, on wavelengths far apart (1310/1490 or 1270/1330 nm). A 100G BiDi sends a single 100G signal per direction using PAM4PAM4 Modulation with four signal levels instead of two (NRZ), so each symbol carries two bits. That fits 100G on one wavelength at the cost of signal-to-noise ratio, which is why it always runs with FEC.: four levels, around 106 Gb/s. Your switch still hands the module four 25G lanes; a DSP inside converts them onto one wavelength. It's the same approach as single-lambda 100G such as DR1, FR1 and LR1, except both directions share one fiber.
- Wavelengths close together — the BX40 uses two channels from the LAN-WDM grid that 100GBASE-LR4 also uses, only 4.56 nm apart. The filter that separates the two directions has to be far more precise than at 1310/1490.
- FEC isn't optional — a PAM4 link is specified for a pre-FEC bit error ratio of up to 2.4 × 10⁻⁴ and depends entirely on FECFEC Forward Error Correction: the transmitter adds parity so the receiver can correct bit errors itself, without retransmission. Often required from 25G up; both ends of the link must use the same FEC. (RS(544,514), KP4). Many modules handle that FEC in their DSP; whether host FEC must then be on or off varies by module. Read the datasheet and set both ports the same. Solid Optics doesn't publish where the FEC sits on our BX20 and BX40. We run these modules ourselves in Huawei S6730-H24X6C-V2 switches, with FEC enabled on the switch. How to spot an FEC mismatch is in FEC explained.
- The standard is new — 1G BX10 has been in IEEE 802.3 for years, 10G BiDi since 802.3cp in 2021. For 100G, IEEE 802.3dk only arrived in March 2026, defining 100GBASE-BR10, -BR20 and -BR40. The working group based it on PAM4 around 1304.6 nm (upstream) and 1309.1 nm (downstream).
That matters in practice: plenty of 100G BiDi modules predate the standard, and "BX20" tells you nothing about wavelengths. For 20 km you'll see 1280/1310 and 1291/1311 nm, among others. Our BX40 uses the 802.3dk wavelengths; our BX20 doesn't. If the far end uses a module from another source, compare the wavelengths on both datasheets, not the label.
BX20 or BX40: work out your power budget first
The BX20 is the default choice: 20 km with a power budgetPower budget The difference in dB between an optic's minimum transmit power and its receiver sensitivity: the loss the link may have. Link loss plus margin must stay within it. of 9.8 dB. It has to cover fiber, connectors, splices and margin for future repairs. How to work that out is in calculating your optical power budget.
If the BX20 falls short, take the BX40. It has an APD receiver and a transmitter up to +7.1 dBm, while its receiver overloads above −2.4 dBm. So the link needs at least 9.5 dB of loss. On a short link, fit an attenuatorAttenuator Passive component that removes a fixed amount of light, for example 5 dB. You place it in front of the Rx port when a long-reach optic on a short link overloads the receiver. or you'll overdrive the receiver at the far end. After plugging in, read the RX power via DOM: the modules report TX and RX power, temperature, bias and voltage.
What about multimode?
100G BiDi exists for multimode too, but it works differently. A 100G-SR1.2 (Cisco's name for it) puts two 50G PAM4 lanes on 850 and 910 nm over two multimode fibers with a duplex LC: 70 m on OM3, 100 m on OM4, 150 m on OM5. Both ends use the same module; there's no U/D pair. You save fibers compared to a 100G-SR4 on MPO (eight fibers), not compared to plain duplexDuplex Link that uses two fibers: one to transmit, one to receive. The default for most SFP and QSFP optics with an LC duplex connector.. Note that Cisco's older QSFP-40/100-SRBD won't link with it. The SR1.2 isn't in our webshop; just ask.
How to order the right pair
- Measure or calculate the loss of your fiber, including connectors and splices.
- Pick the BX20 if you stay within 20 km and 9.8 dB, otherwise the BX40.
- Plan an attenuator for a BX40 on a short link, so the link has at least 9.5 dB of loss.
- Order one U and one D of the same type per link, each with the coding of the switch it goes into.
- Set FEC the same on both ports. With our BX20 and BX40 we run FEC enabled on the switch.
- Read the RX power at both ends via DOM after plugging in.
Still not sure BiDi is the right call at all? Read BiDi vs duplex. If you are, order your pair from the 100G BiDi QSFP28 page with your platform's coding. Want the link measured and handed over as well? Look at our services, or ask an engineer to run the numbers with you.

Founder of FiberNxt and Xyphen IT
Yvan Watchman is the founder of FiberNxt and Xyphen IT. He has been building and running networks and data centre infrastructure in and around Amsterdam for years.
Related products and services
Frequently asked questions
Is 100G BiDi an official standard?
Since March 2026 it is: IEEE 802.3dk defines 100GBASE-BR10, -BR20 and -BR40, all three using PAM4 over one single-mode fiber. Many modules on the market predate that standard and use their own wavelengths. Always compare the wavelengths on the datasheet, not just the label.
Can I connect a 100G BiDi to a 10G BiDi or a 100GBASE-LR4?
No. A 10G BiDi uses different wavelengths and NRZ; an LR4 uses two fibers and four wavelengths. A 100G BiDi link needs a 100G BiDi at both ends: one U and one D of the same type.
Is a multimode 100G BiDi also a U/D pair?
No. A 100G-SR1.2 runs over two multimode fibers with a duplex LC, and both ends use the same module. It saves fibers compared to an SR4 on MPO, not compared to regular duplex.