FOA Fiber patch cable LC-LC OM4 duplex

In stock
Length
Configuration
Length
1 m
SKU
D6O5EEAO300100
Specifications
General
Termination
LC-LC
Media
OM4 (multimode)
Connector
LC duplex
Cable
Length
1 m
Polish
UPC
Jacket
LSZH
Diameter
2 mm
Download datasheet (PDF)
6,23 €
excl. VAT

7,54 € incl. VAT

Pricing is based on your current configuration.

8 in stock
1

Ordering more than we have in stock? We backorder the rest – delivery in ± 1 business day.

Nxt-Level Service

We offer same-day delivery and installation to keep your infrastructure up and running without delay.

Same-day Amsterdam

≤ 45km from Almere

We deliver to datacenters at Science Park, Zuidoost and Schiphol-Rijk, incl. Equinix, Digital Realty, Nikhef and Maincubes.

Same-day NL

> 45km from Almere

Urgent delivery available for other datacenters or customer sites.

OM4 LC-LC: the standard for SR optics

This patch cable connects two LC duplex ports over OM4 multimode fiber (50/125 µm). It is the cable you need between SR optics, such as 10GBASE-SR and 25GBASE-SR, and for patch panels in the data center. LC/UPC at both ends, a 2 mm LSZH jacket and available in multiple lengths.

How far do you get over OM4?

OM4 is multimode fiber with more bandwidth than OM3. So the same optic reaches further:

  • 10GBASE-SR: 400 m over OM4, 300 m over OM3.
  • 25GBASE-SR: 100 m over OM4, 70 m over OM3.
  • 40GBASE-SR4 and 100GBASE-SR4: 150 m and 100 m over OM4, but those use MPO, not LC.

Only use OM4 with multimode optics (SR, SX). An LR or LX optic belongs on single-mode fiber: for that there is the OS2 LC-LC patch cable.

LC duplex, UPC and LSZH

Duplex means two fibers in one cable: one to transmit, one to receive, as every regular optic uses. Both ends are LC/UPC, the common polish for data center optics. The LSZH jacket (low smoke, zero halogen) gives little smoke and no toxic halogens in a fire; in server rooms and offices that is often a requirement.

Choosing the length

Pick the length in the selector. Too long means coiling, and a coil in a cable tray takes space and a proper bend radius. Too short means strain on the connector. The patch cable length calculator works out your route and rounds up to a length we supply. Getting CRC errors on a link? Look at the patch first: a dirty or damaged connector is the most common cause.

Clean is half the job

On multimode you don't always see a dirty connector right away: the link comes up, but with a lower light level and occasional errors. Keep the dust caps on until you install the cable, and clean a connector that was used before plugging it into an optic. After installing, read the RX power via DOM: that tells you at once whether the link has the margin you expect.

Frequently asked questions

What is the difference between OM3 and OM4?

Both are multimode 50/125. OM4 has more bandwidth, so you reach further: 10GBASE-SR does 400 m over OM4 versus 300 m over OM3. Connectors and optics are the same.

Can I use OM4 with an LR optic?

No. LR and LX optics are for single-mode fiber (OS2). They don't work reliably on multimode. Use OM4 with SR and SX optics.

What does LSZH mean?

Low smoke, zero halogen: the jacket gives little smoke and no toxic halogen gases in a fire. In data centers and offices it is often mandatory.

Which length do you need?

Enter rack, U position and route. You get the cable length, rounded up to a length we stock.