LC vs SC, UPC vs APC: which patch cord fits your port

LC/UPC, SC/APC, duplex or simplex: how to read the connector code, tell what's on your switch, ODF or fiber wall socket, and order the right patch cord.

5 min readBy Yvan Watchman

LC or SC, UPC or APC. Size: LC or SC: LC: 1.25 mm ferrule, on almost every SFP; SC: 2.5 mm ferrule, often at the wall outlet. End face: UPC or APC: UPC: blue; APC: green, polished at 8 degrees; Never green into blue, not even briefly. They fit mechanically. That's exactly what makes it dangerous.

You need to order a patch cord and the shop wants to know: LC/UPC, SC/UPC or SC/APC? Or you're looking at the fiber termination box in your utility cupboard, see a small green plug and wonder what that means for your switch. By the end of this article you'll know what those letters stand for, how to tell from the port what you need, and which cord to order, including when the two ends don't match.

Order a patch cord one end at a time

A connector code has two parts: the connector body (LC or SC) and how the end face is polished (UPC or APC). LC/UPC is an LC connector with a flat end face; SC/APC is an SC connector with an angled one.

A patch cord has two ends, and they don't have to be the same. So look at the port on each end first, then order.

LC or SC: it's about size

The difference between LC and SC is mostly size. SC has a 2.5 mm ferrule and snaps in with a push-pull motion. LC has a 1.25 mm ferrule, half the size. Both are defined in IEC standards (IEC 61754-4 for SC, IEC 61754-20 for LC).

Where you'll find them:

  • LC — on nearly every fiber SFP, SFP+ and SFP28, and on most single-mode QSFP28s. Parallel optics such as SR4 use MPO. The small size is what lets a duplex LC fit the narrow SFP housing.
  • SC — on the fiber wall socket at home or in the office (the FTU), on many ODFs (optical distribution frames) and in older patch panels. SC was the connector in TIA-568-A, before LC took over.

UPC or APC: the end face

The second half of the code is about how the tip of the ferrule is polished. A UPC end face is not angled, just slightly domed. An APC end face is polished at an 8-degree angle. That angle sends reflected light into the cladding instead of back towards the laser.

You see this in the return loss, the amount of light reflected back (a higher number means less reflection). Common specs are at least 50 dB for UPC and at least 60 dB for APC. Older PC sits around 40 dB. For Ethernet in your data center, 50 dB is plenty. APC shows up where reflections actually hurt: PON networks (GPON, XGS-PON), RF video over fiber and long WDM links. That's why APC is so common in provider networks.

The color gives it away, following the TIA-568 convention:

ConnectorColorTypically
UPC (or PC), single-modebluetransceivers, data center, some FTUs
APC, single-modegreenPON, many FTUs
UPC, multimodebeige or aqua (OM4 is often violet in practice)SR optics in the rack

What the jacket color tells you is covered in our article on fiber patch cable color codes.

Never green into blue

Never mate an APC connector with a UPC connector, not even "just to test". They fit mechanically, and that's exactly what makes it dangerous. The end faces meet at an angle, the cores don't touch, and you lose a lot of light and reflection goes up. Worse, you can damage both end faces, including the one in your transceiver.

PC and UPC are both flat and mate with each other just fine. The problem is only the jump between angled and flat.

Duplex or simplex

A regular optic transmits on one fiber and receives on the other. That calls for a duplex patch cord: two fibers, two connectors per end, clipped together.

A BiDi optic transmits and receives on a single fiber. It has one connector, usually a simplex LC, so it needs only one fiber. Our SFP-1G BiDi has an LC simplex connector.

The FTTH case: SC on the wall, LC in your switch

If you want to connect your own router or switch with a BiDi SFP to an AON fiber line, there's usually an SC on the wall and an LC in your SFP. So you need a hybrid cord: SC on one end, LC/UPC on the other. The odd green FTU has an LC/APC connector; then you need an LC/APC to LC/UPC cord.

  • Check the connector on the FTU: SC or LC, blue or green?
  • Choose an SC/UPC to LC/UPC cord for a blue SC, SC/APC to LC/UPC for a green SC, LC/APC to LC/UPC for a green LC.
  • Plug the connector of one fiber into the FTU and the LC of that same fiber into your BiDi SFP.
  • Clean both connectors before you plug them in.

We sell an OS2 SC/UPC to LC/UPC patch cord. It's duplex: with a BiDi SFP you use one of the two fibers and leave the other unused. If your wall socket has a green SC/APC, we can supply an SC/APC to LC/UPC cord on request; it isn't in the shop yet.

To find out which technology and connector your provider uses, try our which SFP for my fiber tool.

What to do now

Check the connector on both ends: LC or SC, blue or green. Between two SFPs in a rack, that's almost always an OS2 LC/UPC patch cord; you'll find every variant under cables. Clean the end faces with a Clear Connection Tool before plugging in. See a green connector and not sure what's behind it? Ask us before you order.

Yvan Watchman

About the author

Yvan Watchman

Founder of FiberNxt and Xyphen IT

Yvan Watchman is the founder of FiberNxt and Xyphen IT. He has been building and running networks and data centre infrastructure in and around Amsterdam for years.

LinkedIn profile

Related products and services

Frequently asked questions

What is the difference between LC and SC?

Size. SC has a 2.5 mm ferrule, LC a 1.25 mm one, half the size. Optically they do the same job. SFP modules almost always have LC; you mostly see SC on fiber wall sockets at home, on ODFs and on older patch panels.

Can I plug an APC connector into a UPC port?

No. An APC end face is polished at 8 degrees, a UPC end face is not. The cores don't meet, you lose a lot of light and you can damage both end faces, including the one inside a transceiver. If you need to go from green to blue, use a hybrid patch cord.

Which patch cord do I need between my fiber wall socket and a BiDi SFP?

On an AON line: usually SC on the socket side, LC/UPC on the SFP side. If the SC connector on the socket is blue, take SC/UPC to LC/UPC; if it's green, take SC/APC to LC/UPC. The odd green socket has LC/APC; then you need LC/APC to LC/UPC.