FOA Fiber patch cable LC-LC OS2 single-mode

In stock
Length
Configuration
Length
2 m
SKU
D7O5EEAA300200
Specifications
General
Termination
LC/UPC-LC/UPC
Media
OS2 (single-mode)
Connector
LC duplex
Cable
Length
2 m
Polish
UPC
Jacket
LSZH
Diameter
2 mm
Fiber class
G.657A
Download datasheet (PDF)
6,23 €
excl. VAT

7,54 € incl. VAT

Pricing is based on your current configuration.

2 in stock
1

Ordering more than we have in stock? We backorder the rest – delivery in ± 1 business day.

Nxt-Level Service

We offer same-day delivery and installation to keep your infrastructure up and running without delay.

Same-day Amsterdam

≤ 45km from Almere

We deliver to datacenters at Science Park, Zuidoost and Schiphol-Rijk, incl. Equinix, Digital Realty, Nikhef and Maincubes.

Same-day NL

> 45km from Almere

Urgent delivery available for other datacenters or customer sites.

OS2 LC-LC: for everything beyond the rack

This patch cable connects two LC duplex ports over OS2 single-mode fiber. It is the cable for LR, ER and ZR optics, for cross-connects in the data center and for any link longer than a few hundred meters. The fiber is G.657A: insensitive to tight bends, so it keeps its values even in a full cable tray.

Single-mode: the optic sets the distance, not the cable

Over OS2 the optic decides how far you get: 10 km for LR, 40 km for ER, 80 km for ZR. A patch cable of a few meters adds hardly any loss, as long as the connectors are clean. Only use OS2 with single-mode optics (LX, LR, ER, ZR); SR and SX optics belong on multimode, for which there is the OM4 LC-LC patch cable.

G.657A: bend insensitive

Regular single-mode fiber (G.652D) loses light when bent too tightly. G.657A fiber tolerates a much smaller bend radius without extra loss. In a rack with tight cable management or a full tray, that saves you faults that are otherwise hard to find. Mind you: the connector itself stays sensitive, so never bend right behind the LC.

Connectors and jacket

  • LC/UPC at both ends: the common polish for data center optics. If you have a green SC/APC port, this cable doesn't fit; for that you need an APC cable.
  • Duplex: two fibers, as every regular optic uses. For BiDi optics you use one.
  • LSZH, 2 mm: little smoke and no halogens in a fire, often a requirement in server rooms.

Pick the length in the selector, or work out your route with the patch cable length calculator.

For cross-connects and long links

On a cross-connect in the data center your link often runs through one or more patch panels. Every mated pair adds a few tenths of a dB of loss. With an LR optic over a few hundred meters you have plenty of margin, but with ER or ZR over long distances every connection counts. Work out your link budget beforehand and read the RX power via DOM after installing, so you know you're within the optic's specification.

Frequently asked questions

Which optics do I use with an OS2 patch cable?

Single-mode optics: 1000BASE-LX, 10GBASE-LR, ER and ZR, 25GBASE-LR, 100GBASE-LR4 and BiDi. SR and SX optics belong on multimode (OM3 or OM4).

What is the advantage of G.657A?

G.657A fiber loses almost no light in a tight bend. In a full rack or a narrow cable tray you keep stable light levels.

Can I use this cable for BiDi?

Yes. A BiDi optic uses one fiber: you use one of the two fibers in this duplex cable and the other stays free. If the two LCs are held together by a clip, remove it so a single LC fits the simplex port.

Which length do you need?

Enter rack, U position and route. You get the cable length, rounded up to a length we stock.

Related products