FOA Fiber patch cable SC/UPC-LC/UPC OS2 single-mode

On backorder – delivery in ± 1 business day
Length
Configuration
Length
2 m
SKU
D7O5CEAA300200
Specifications
General
Termination
SC/UPC-LC/UPC
Media
OS2 (single-mode)
Connector
SC/LC duplex
Cable
Length
2 m
Polish
UPC
Jacket
LSZH
Diameter
2 mm
Fiber class
G.657A
Download datasheet (PDF)
6,13 €
excl. VAT

7,42 € incl. VAT

Pricing is based on your current configuration.

On backorder – delivery in ± 1 business day
1

Nxt-Level Service

We offer same-day delivery and installation to keep your infrastructure up and running without delay.

Same-day Amsterdam

≤ 45km from Almere

We deliver to datacenters at Science Park, Zuidoost and Schiphol-Rijk, incl. Equinix, Digital Realty, Nikhef and Maincubes.

Same-day NL

> 45km from Almere

Urgent delivery available for other datacenters or customer sites.

SC to LC: from the FTU or patch panel to your SFP

This patch cable has SC/UPC at one end and LC/UPC at the other, over OS2 single-mode fiber. It is the cable you need when your fiber arrives on a blue SC port, such as a fiber provider's FTU or an SC patch panel, and your switch, router or firewall has an SFP with an LC connector.

At home or in the office: blue FTU and a BiDi SFP

On an AON fiber connection you can replace the provider's box with your own SFP module, usually a BiDi module: the GLC-BX-U20-SO. If your FTU is blue, it is SC/UPC and this cable fits. A green FTU is SC/APC: that needs an APC cable, not this one. Which module and cable your provider needs is in the tool which SFP do I need for my fiber connection.

Duplex cable, one fiber for BiDi

This cable is duplex: two fibers side by side. A BiDi module transmits and receives over one fiber, so you use one of the two. Plug the SC of that fiber into the FTU and the LC of the same fiber into the module; the second fiber stays free. If the connectors are held together by a clip, remove it. No link? Switch to the other fiber first: chances are you're using the SC and LC of different fibers.

In the data center

In server rooms you still come across SC, mainly on older patch panels and ODFs. With this cable you connect such a panel to a modern LC optic, using both fibers for a regular duplex optic such as 10GBASE-LR. If both ends are LC, take the OS2 LC-LC patch cable.

G.657A, LSZH and length

The fiber is G.657A: insensitive to tight bends, handy in a utility cupboard or a full cable tray. The jacket is 2 mm LSZH: little smoke and no halogens in a fire. We supply lengths from 0.5 to 35 m; pick what you need in the selector, or work out your route with the patch cable length calculator.

Frequently asked questions

Does this cable fit my fiber FTU?

If the port is blue, yes: that is SC/UPC. A green port is SC/APC; this cable doesn't mate properly with it and you damage the connectors.

I have a BiDi module, why is this cable duplex?

A BiDi module uses one fiber. You use one of the two fibers in this cable: the SC in the FTU and the LC of the same fiber in the module. The other fiber stays free.

Which lengths are available?

From 0.5 to 35 m, including 1, 2, 5, 15 and 25 m. Pick the length in the selector on this page.

Which length do you need?

Enter rack, U position and route. You get the cable length, rounded up to a length we stock.