Praxisnahe Artikel über Transceiver, Kabel und das Rechenzentrum. Was funktioniert, was nicht, und warum.
Questions and answersOnly one fiber but you need 100G? How a 100G BiDi QSFP28 works, how it differs from 1G and 10G BiDi, BX20 or BX40, FEC, attenuators and what to order.
5 Min. Lesezeit
LR4, CWDM4 or single-lambda DR1, FR1 and LR1? How they differ in lanes, PAM4 and FEC, which ones interoperate, and what to pick with 400G on the roadmap.
5 Min. Lesezeit
Planning a 400G spine/leaf or DCI upgrade? How to choose between QSFP-DD and OSFP and between SR8, DR4, XDR4, FR4, LR4 and ZR, with breakout, power and FEC.
5 Min. Lesezeit
High loss, CRC errors, or about to patch new links? How to inspect and clean connectors, bulkheads and transceiver ports, with a printable checklist.
5 Min. Lesezeit
RJ45 in an SFP or SFP+ port? What a 1G-T or 10G-T module draws, how hot it runs, how far it reaches, and when a DAC or fiber is the smarter choice.
5 Min. Lesezeit
CRC errors climbing on your uplink? Read DOM on both ends, find the real cause, and swap the transceiver last. A troubleshooting order backed by data.
6 Min. Lesezeit
Connecting your rack to a carrier, AMS-IX or cloud on-ramp? What a cross-connect is, what the LOA says, real lead times and how to test the link.
5 Min. Lesezeit
One fiber pair and not enough capacity? How CWDM and DWDM differ in wavelengths, channels, distance and cost, and when to pick which.
5 Min. Lesezeit
Passive DAC, active copper, AOC or transceivers with a patch cord? Reach, power, cost, cable bulk, breakout and coding compared, plus a checklist.
5 Min. Lesezeit
DAC, AOC or optics in the rack? Where latency in a short link really comes from, why a passive DAC wins, and when those nanoseconds are worth chasing.
5 Min. Lesezeit
A TIA-606 labeling scheme for rack, patch panel, port and patch cable: what goes on the label, what goes in NetBox, and how remote hands find the right cable.
5 Min. Lesezeit
Switch rejects your optic? The command or setting per platform to allow third-party optics, what it costs you in support, and why the right coding is better.
5 Min. Lesezeit
Light levels fine, link still down or full of errors? It's often FEC. Which link needs which FEC, why a mismatch kills the link, and how to read the counters.
5 Min. Lesezeit
Yellow, aqua, orange, violet, a blue or green connector: what fiber patch cable colors mean under TIA-598, and why you still read the print on the jacket.
4 Min. Lesezeit
Which fiber patch cable lengths exist, how to measure patch panel to switch, and why one size up beats one that's 20 cm short.
4 Min. Lesezeit
G.657.A1, A2 or G.652.D on a single-mode patch cord? What the codes mean, which bend radius and macrobend limits apply, and what bend-insensitive won't fix.
5 Min. Lesezeit
Your switch shows 38 mA laser bias current or a bias high alarm. What the number means, why there's no fixed normal and which pattern really points to wear.
5 Min. Lesezeit
LC/UPC, SC/APC, duplex or simplex: how to read the connector code, tell what's on your switch, ODF or fiber wall socket, and order the right patch cord.
5 Min. Lesezeit
Planning 40G, 100G or 400G, or a dense row of racks? When MPO trunks with cassettes pay off, when duplex LC is enough, and where polarity goes wrong.
5 Min. Lesezeit
An 8 km link with four patch points: will an LR do, or is it marginal? How to work out power budget, link loss and margin, with three worked examples.
5 Min. Lesezeit
OS2 or OM4, OM3 or OM4? Distances per standard, what optics and fiber really cost, and when you're better off running single-mode everywhere.
4 Min. Lesezeit
Remove the KPN box and plug the fiber straight into your own router? How to tell AON, GPON and XGS-PON apart, which SFP or ONT you need and what to configure.
5 Min. Lesezeit
One 100G port, four 25G servers or switches? When to pick a breakout DAC or AOC, when SR4 or PSM4 with an MPO fanout, and what to configure first.
5 Min. Lesezeit
Dead optic or a turn-up that has to happen today? What to tell us, how to pick the coding and how the optic gets from receiving into your rack.
5 Min. Lesezeit
No link, or a link that keeps flapping? A printable checklist in the right order: port, BiDi pair, reach, fiber, connectors, DOM, too much light and the swap test.
5 Min. Lesezeit
Yearly spares check per site: count your spare optics, check coding after upgrades and hardware swaps, test them and review your SLAs. With a printable checklist.
4 Min. Lesezeit
Rolling out dozens or hundreds of optics? How to test coding, recognition, DOM, link and errors up front, how long to soak them and what to record per port.
5 Min. Lesezeit
What coding in a transceiver's EEPROM does, why switches check it, what you actually risk with third-party optics and how to order the right coding.
5 Min. Lesezeit
Your switch says unsupported transceiver, err-disables the port or the link stays down. How to read what the switch sees, and fix it with the right coding.
5 Min. Lesezeit
What the SFP port on your switch is, what an SFP module does, and how to choose one in five steps: speed, fiber type, reach, connector and coding.
5 Min. Lesezeit
SFP LX vs SX and 10GBASE-SR vs LR: what each reach code means, which come from IEEE 802.3, which fiber and wavelength they need, and how to choose.
6 Min. Lesezeit
SFP vs SFP+, SFP28 vs SFP+ and QSFP28 vs QSFP+: what the difference is, which module works in which port, and how to get from QSFP28 to SFP28.
5 Min. Lesezeit
Your optic reads -14.2 dBm. Good or bad? Receive sensitivity and overload per optic type, how much margin to keep, and what to fix in which order.
6 Min. Lesezeit
Where do our optics come from, who tests them and what happens when one isn't right? On Solid Optics, testing, lifetime warranty and how we count RMAs.
5 Min. Lesezeit
Two BiDi optics in and no link? What U and D, 1310/1490, 1270/1330 and BX10/20/40 mean, what the standard actually says, plus an ordering checklist.
5 Min. Lesezeit
Your switch logs an Rx power low alarm. How to read DOM/DDM on Cisco, Juniper, Arista and MikroTik, what the values mean and where to look first.
5 Min. Lesezeit
Your dashboard shows DOM critical or a laser bias current high alarm. What the four thresholds mean, who sets them and the order to fix it in.
5 Min. Lesezeit
Supply chain security for transceivers: grey market, coding, per-item test reports and what NIS2 requires. Includes a practical buyer's checklist.
5 Min. Lesezeit
BiDi or duplex? How a BiDi transceiver works over a single fiber, when it actually pays off, when duplex is the smarter call, and the mistakes to avoid.
5 Min. Lesezeit
Dead transceiver at 4 pm? Which spare optics to keep ready, what to record per port, and how to get a replacement in your rack the same day.
5 Min. Lesezeit